技術(shù)文章 / article 您的位置:網(wǎng)站首頁 > 技術(shù)文章 > Acrel anti-backflow meter apply in the Philippines photovoltaic project

Acrel anti-backflow meter apply in the Philippines photovoltaic project

更新時間: 2022-01-08  點擊次數(shù): 518次
1.Background
    With the development of photovoltaic industry, the capacity of village-level transformers and industrial power transformers and the installed capacity of photovoltaic projects are saturated in some areas.The power grid company requires the photovoltaic grid-connected system to be a non-backflow current generation system, which means that the electricity generated by the photovoltaic grid-connected system is consumed by the local load, and the excess electricity is not allowed to be sent to the upper power grid through the low-voltage distribution transformer in reverse direction.
    Photovoltaic inverter in photovoltaic components will produce direct current into alternating current (ac), has the dc component and harmonic mixing, unbalanced three phase current, output power of uncertainty, such as the current basic didn't take effective management measures, therefore, when there is power to the utility grid, will generate harmonic pollution to power network, easy cause power grid voltage fluctuation and flicker, etc.,If there are many such power sources to transmit electricity to the grid, the power quality of the grid will be seriously degraded.Therefore, this kind of photovoltaic power generation system must be equipped with anti-backflow current facilities to prevent the occurrence of reverse power.
    When the photovoltaic power generation is greater than the load demand, the inverse power will be generated.So we need instruments to determine that Inverter has power output, and then by the instrument through RS485 communication signal and inverter data interaction, adjust the inverter output power, so that its output power and power balance.
 
2.Project Overview
    A photovoltaic power generation company in the Philippines contacted our company to look for anti-backflow current meters. After proper connection agreement, we will purchase ACR10R-D16TE from our company.

3.Anti-backflow detection meter
    When the photovoltaic power generation is greater than the load demand, reverse power will be generated. Therefore, we need an meter to determine that the inverter has over-power output, and then the meter sends a signal through RS485 communication to interact with the inverter data to adjust the output power of the inverter to balance the output power and the electrical power.
4.Function 
 
 

5.Wiring
 


6.Typical Connection

 Bibliography
1.Solutions for enterprise micro-grid system 


聯(lián)


99久久精品无码一区二区毛片| 中文字幕亚洲爆乳无码专区| 精品欧美一区二区三区久久久| 西西人体www大胆高清视频| 局长含着秘书的小奶头| 亚洲色大成网站WWW久久九九 | yyy6080韩国三级理论| 妺妺窝人体色WWW婷婷| 粗大的内捧猛烈进出在线视频| 日本a级作爱片金瓶双艳| 久久久久99精品成人片试看| 午夜精品一区二区三区在线视| 少妇扒开双腿自慰出白浆| 老司机精品视频| 性色AV蜜臀AV色欲AV| 精品少妇一区二区三区视频| 色婷婷久久啪啪一区二区| 噜噜狠狠色综合久色a站网址| 亚洲AV无码乱码在线观看性色| 日本强伦姧人妻一区二区 | 东京热加勒比高清无线| 337P日本欧洲亚洲大胆色噜噜| 欧美18videosex性欧美| 日产国产亚洲精品系列p| 性熟妇videos另类hd| 精品人妻AV一区二区三区| 亚洲AV中文无码乱人伦在线咪咕| 金瓶悔1一5扬思敏完整版| 日本高清视频www| 人与禽性视频77777| 玩两个丰满老熟女在线视频| 国色天香久久久久久久小说| 蜜臀AV午夜一区二区三区| 国产高清在线A视频大全| 动漫精品一区二区三区在线观看| 精品人妻无码一区二区三区下载| 被多个男人调教奶头玩奶头| 蜜桃视频在线观看| 国产高潮流白浆喷水在线观看| 奇米777四色影视在线看| 看AV免费毛片手机播放|